Septic Alarms

on Friday, 10 March 2017.

As a Monitoring and Maintenance (M&M) provider, we occasionally have customers calling us during a septic alarm. One of the first questions we will ask the customer is if they have silenced the alarm already. If you have a septic system that requires a panel, and all systems other than gravity require a panel, you're going to experience an alarm at some point during the lifetime of your system. We always want our customers to call us with septic alarms, as there could be a variety of things causing the alarm, however, it's important to know how to silence the alarm, especially if the alarm goes off in the middle of the night. Most panels will have a button on the front or the side that can be pushed to silence the alarm. Below we have a Nuwater panel, where you can see there are two alarm lights, a level alarm and a low air alarm. When an alarm goes off, the button can be pushed to slience the alarm. It's very important to note that silencing the alarm does not mean the alarm has been resolved. It simply means the noise will stop. Once you've silenced the alarm, please call our office at 360-698-8488 to discuss the next steps. 
 
Please note that unless you have a Nuwater panel, your panel will look different than the one pictured. It's a good idea to take a look at your panel, and determine where the button to silence an alarm is located, before you experience an alarm. 

 

outside Nuwater panel

Vented Lids For An Aerobic Treatment Unit

on Friday, 04 November 2016.

Pretreatment systems, or Aerobic systems, are now being required to have vented lids installed on all new systems. The Aerobic Treatment Unit, or ATU, is the pretreatment device in which the effluent must go through before going out to the drain field. Vented lids were not always required, so most ATUs do not have them. The reason for the change has to do with the algae that can, and does, build up in a system. When a lid is vented, it can reduce this build up, and will also reduce the frequency of pump outs. Charcoal vented lids can help with the septic smell. Home owners are not currently required to change the ATU lids to the vented ones, however, it is recommended. Below are photos of two different types of vented lids. The top photo is the older version, which is no longer recommended as groundwater can get in, as the holes are on the sides. The bottom photo is the current vented lid, which can be purchased at HD Fowler in Gorst or Ferguson's in Silverdale. Contact information for both can be found here

 

IMG 8500